Recommendations for assembly and installation. Heating systems for country and country houses

Characteristics

The floor gas non-volatile single-circuit boiler ZHMZ AOGV-17.4-3 Comfort N with an open combustion chamber is designed for heating residential, domestic, industrial and other premises up to 140 sq.m. On the front side of this model, a removable chute is installed that covers the automation unit and the gas burner. The advantage of the ZhMZ AOGV-17.4-3 Comfort N boiler, the most popular among consumers, is the ability to work in systems with natural and forced air circulation, the boiler is compatible with any material from which the heating system is made (steel, cast iron, polypropylene, metal-plastic), as well as its work does not depend on electricity and can be configured to work on natural or liquefied gas.

Peculiarities

  • Complete with imported automation unit
  • Provides convenience and comfort in use
  • Has a compact design
  • Allows you to select the temperature mode
  • Has the ability to adjust the height of the ignition flame
  • Allows you to adjust the gas pressure with a built-in regulator
  • The safety of the boiler is ensured by the additionally installed automatic overheating
  • Ignition lockout after flame out
  • The convenient location of the automation unit and the built-in piezo ignition provide easy start-up of the boiler
  • Classic cylindrical shape
  • Stable operation at low gas pressure
  • Equipped with Honeywell gas valve (USA)
  • Equipped with a pointer thermometer, which allows you to visually control the temperature of the coolant in the heating system
  • The heat exchanger is made of high-quality metal produced by NLMK
  • The thickness of the heat exchanger steel in the burner area is 2.5 mm
  • Screw turbulators are made of steel 2 mm thick and increase the efficiency of the boiler
  • Heating system coolant - softened water or household antifreeze
  • The service life of the boiler is at least 14 years

Specifications

Boiler type Gas

Mounting method Floor

Combustion chamber type open

Thermal power, kW 17.4

Natural gas Yes

LPG Yes

Chimney diameter, mm 135

Steel

non-volatile Yes

Manufacturer Russia

Boiler type Gas

Working principle Convection

Number of circuits Single circuit

Mounting method Floor

Combustion chamber type open

Thermal power, kW 17.4

Natural gas Yes

LPG Yes

Chimney diameter, mm 135

Primary heat exchanger material Steel

non-volatile Yes

Manufacturer Russia

Power consumption, kW 17,4

Burner type Injection

Tank capacity, l 64

Ignition time, no more, sec 60

Overall dimensions (HxWxD), mm 1045-1055x415-425x475-485

Water pressure in the heating system, no more than, kPa 100

Diameter of heating pipes, inch G2

Gas supply fitting diameter, inch G 3/4

Range of maintaining the temperature of the heat carrier in the heat exchanger, ° С 50-90

Leak allowed, no more than, cc/h 70

Carbon monoxide index, no more than, vol.% 0.05

Number of screw turbulators, pcs 8

Efficiency in heating mode, not less than, % 88

Boiler weight (without packaging), no more than, kg 49

Minimum / maximum pressure of natural gas, Pa (mm w.c.) 635 (65)/1764 (180)

Minimum/Maximum Pressure liquefied gas, Pa (mm water column) 1960 (200)/3528 (360)

Minimum / maximum vacuum in the chimney, Pa (mm water column) 2,94 (0,3)/29,4 (3,0)

Outer diameter of the connecting branch pipe of the gas exhaust device, mm 133-137

Rated pressure natural gas, Pa (mm water column) 1274 (130)

Nominal pressure of liquefied gas, Pa (mm water column) 2940 (300)

Heating of premises with heat loss no more than, kW 14.5

Heated room area H=2.7 m high, no more than, sq.m 100-140

Distance from the floor to the end of the outlet pipe of the heat exchanger, mm 1045-1055

Distance from the floor to the axis of the inlet pipe of the gas pipeline, mm 835-845

Distance from the floor to the axis of the inlet pipe of the heat exchanger, mm 287-297

Consumption of natural gas, no more than, m3/h 1.87

Consumption of liquefied gas, no more than, cubic m / h (kg / h) 0,65 (1,3)

Ignition type Piezo ignition

High reliability

The safety of the ZhMZ AOGV-17.4-3 Comfort N boiler operation is ensured by automation, which is triggered when the flame on the igniter goes out, there is no draft in the chimney, the gas supply is interrupted or the gas pressure drops below the permissible value, the temperature of the coolant in the boiler tank rises above 93 - 100 °C. The pressure in the closed heating system in which the boiler can be used must not exceed 2.0 kgf/cm2.

floor gas non-volatile single-circuit boiler with an open combustion chamber

About delivery

    • Delivery is carried out on working days from 12:00 to 18:00 Moscow time
    • Delivery outside the Moscow Ring Road is 50 rubles / km and is paid according to the actual distance traveled by the car. We recommend using the Yandex.Maps service to find out the exact distance.
    • Delivery at a distance of more than 130 km from Moscow is carried out through transport and logistics companies
    • Delivery on weekends, holidays, urgent delivery the same day, delivery of the order at exactly the specified time is carried out at increased rates and after agreement with the store
    • Upon delivery of the order by truck, the unloading of the goods is carried out by the Buyer
    • Approximately 1 hour before delivery, the forwarder contacts the Buyer. If it is impossible to confirm the acceptance and transfer of the order to the appointed address, the delivery is canceled
    • Pickup is carried out after the store confirms the movement of goods to the point of issue of the order
    • The Forwarder does not advise on technical parameters and functional features goods, their compatibility, cost, etc. This information can be obtained by calling our office at the contact numbers
    • Our trucks deliver orders along pre-planned routes on a schedule that provides for high accuracy. Therefore, we ask you to be understanding that unloading, checking and payment for goods must be made within 10-15 minutes.

About payment

    • We accept payment for the goods only in rubles for cash or bank transfer
    • The price of the goods includes the VAT rate of 20%
    • Sending an order to the regions of the Russian Federation through transport companies is made to the Buyer's address only after 100% prepayment
    • The exact cost of payment is calculated from the cost of goods and the cost of delivery (outside the Moscow Ring Road, for urgency, for the exact delivery time) of the order. Please take this into account

Mounting

The specialists of our company carry out a paid visit to the site, while the cost of the visit is refunded upon conclusion of the contract, on the spot they will agree with you on the terms, stages and scope of work, select equipment and components.

After the conclusion of the Contract and the prepayment, the delivery, installation and commissioning of the equipment is carried out at the appointed time. Upon completion of the work, Acts are drawn up and full payment is made.

The prices for the departure of a specialist and installation of equipment can be found at the link.

Service and repair

At your request, the company is ready to conclude an annual service agreement with you. The advantage is an extended warranty for the work performed and preferential maintenance of equipment.

If such an Agreement has not been concluded, then you can contact the specialized service centers at

Characteristics

Shipping and payment

Installation and service

Reviews 0

Spare parts

Characteristics

The floor gas non-volatile single-circuit boiler ZHMZ AOGV-17.4-3 Universal H with an open combustion chamber is designed for heating residential, domestic, industrial and other premises up to 140 sq.m. On the front side of this model, a removable chute is installed that covers the automation unit and the gas burner. The advantage of the ZhMZ AOGV-17.4-3 Universal H boiler is the ability to work in systems with natural and forced air circulation, the boiler is compatible with any material from which the heating system is made (steel, cast iron, polypropylene, metal-plastic), as well as its operation does not depend on electricity and can be configured to operate on natural or liquefied gas.

Peculiarities

  • Complete with imported automation unit
  • Has a compact design
  • Adjusting the gas flow on the pilot burner
  • The built-in gas pressure stabilizer ensures a stable rated power of the boiler, regardless of fluctuations in gas pressure in the network gas pipeline
  • Smooth switching on and off of the main burner
  • Classic cylindrical shape
  • Stable operation at low gas pressure
  • The flow type heat exchanger is made of high-quality metal produced by NLMK
  • Heat exchanger steel thickness in the burner area - 2.5 mm
  • Screw turbulators are made of steel 2 mm thick and increase the efficiency of the boiler
  • Equipped with gas valve EuroSit (Italy)
  • Equipped with pointer thermometer and built-in piezo ignition
  • For the convenience of the consumer, the control is located in the upper part of the boiler.
  • Heating system coolant - softened water or household antifreeze
  • Service life of at least 14 years

Specifications

Boiler type Gas

Mounting method Floor

Combustion chamber type open

Thermal power, kW 17.4

Natural gas Yes

LPG Yes

Chimney diameter, mm 135

Steel

non-volatile Yes

Manufacturer Russia

Boiler type Gas

Working principle Convection

Number of circuits Single circuit

Mounting method Floor

Combustion chamber type open

Thermal power, kW 17.4

Natural gas Yes

LPG Yes

Chimney diameter, mm 135

Primary heat exchanger material Steel

non-volatile Yes

Manufacturer Russia

Power consumption, kW 17,4

Burner type Injection

Tank capacity, l 64

Ignition time, no more, sec 60

Overall dimensions (HxWxD), mm 1045-1055x415-425x475-485

Water pressure in the heating system, no more than, kPa 100

Diameter of heating pipes, inch G2

Gas supply fitting diameter, inch G 3/4

Range of maintaining the temperature of the heat carrier in the heat exchanger, ° С 50-90

Leak allowed, no more than, cc/h 70

Carbon monoxide index, no more than, vol.% 0.05

Number of screw turbulators, pcs 8

Efficiency in heating mode, not less than, % 88

Boiler weight (without packaging), no more than, kg 49

Minimum / maximum pressure of natural gas, Pa (mm w.c.) 635 (65)/1764 (180)

Minimum / maximum pressure of liquefied gas, Pa (mm water column) 1960 (200)/3528 (360)

Minimum / maximum vacuum in the chimney, Pa (mm water column) 2,94 (0,3)/29,4 (3,0)

Outer diameter of the connecting branch pipe of the gas exhaust device, mm 133-137

Nominal pressure of natural gas, Pa (mm.water column) 1274 (130)

Nominal pressure of liquefied gas, Pa (mm water column) 2940 (300)

Heating of premises with heat loss no more than, kW 14.5

Heated room area H=2.7 m high, no more than, sq.m 100-140

Distance from the floor to the end of the outlet pipe of the heat exchanger, mm 1045-1055

Distance from the floor to the axis of the inlet pipe of the gas pipeline, mm 711-721

Distance from the floor to the axis of the inlet pipe of the heat exchanger, mm 287-297

Consumption of natural gas, no more than, m3/h 1.87

Consumption of liquefied gas, no more than, cubic m / h (kg / h) 0,65 (1,3)

Ignition type Piezo ignition

High reliability

The safety of the ZhMZ AOGV-17.4-3 Universal N boiler operation is ensured by automation, which is triggered when the flame on the igniter goes out, there is no draft in the chimney, the gas supply is interrupted or the gas pressure drops below the permissible value, the temperature of the coolant in the boiler tank rises above 93 - 100 °C. The pressure in the closed heating system in which the boiler can be used must not exceed 2.0 kgf/cm2. Boiler ZhMZ AOGV-17.4-3 Station wagon N has the ability to connect a boiler (purchased separately) to ensure hot water.

floor gas non-volatile single-circuit boiler with an open combustion chamber

About delivery

    • Delivery is carried out on working days from 12:00 to 18:00 Moscow time
    • Delivery outside the Moscow Ring Road is 50 rubles / km and is paid according to the actual distance traveled by the car. We recommend using the Yandex.Maps service to find out the exact distance.
    • Delivery at a distance of more than 130 km from Moscow is carried out through transport and logistics companies
    • Delivery on weekends, holidays, urgent delivery the same day, delivery of the order at exactly the specified time is carried out at increased rates and after agreement with the store
    • Upon delivery of the order by truck, the unloading of the goods is carried out by the Buyer
    • Approximately 1 hour before delivery, the forwarder contacts the Buyer. If it is impossible to confirm the acceptance and transfer of the order to the appointed address, the delivery is canceled
    • Pickup is carried out after the store confirms the movement of goods to the point of issue of the order
    • The forwarder does not consult on the technical parameters and functional features of the goods, their compatibility, cost, etc. This information can be obtained by calling our office at the contact numbers
    • Our trucks deliver orders along pre-planned routes on a schedule that provides for high accuracy. Therefore, we ask you to be understanding that unloading, checking and payment for goods must be made within 10-15 minutes.

About payment

    • We accept payment for the goods only in rubles for cash or bank transfer
    • The price of the goods includes the VAT rate of 20%
    • Sending an order to the regions of the Russian Federation through transport companies is made to the Buyer's address only after 100% prepayment
    • The exact cost of payment is calculated from the cost of goods and the cost of delivery (outside the Moscow Ring Road, for urgency, for the exact delivery time) of the order. Please take this into account

Mounting

The specialists of our company carry out a paid visit to the site, while the cost of the visit is refunded upon conclusion of the contract, on the spot they will agree with you on the terms, stages and scope of work, select equipment and components.

After the conclusion of the Contract and the prepayment, the delivery, installation and commissioning of the equipment is carried out at the appointed time. Upon completion of the work, Acts are drawn up and full payment is made.

The prices for the departure of a specialist and installation of equipment can be found at the link.

Service and repair

At your request, the company is ready to conclude an annual service agreement with you. The advantage is an extended warranty for the work performed and preferential maintenance of equipment.

If such an Agreement has not been concluded, then you can contact the specialized service centers using the link.


1 2 3 4 5 Efficiency factor of the device Efficiency (in continuous operation), %, not less than:
- in heating mode
- DHW mode Type of gas
- natural according to GOST 5542-87
- liquefied according to GOST 20448-80 Gas pressure, Pa (mm water column) natural:
  • - nominal
  • - minimum / maximum
  • 1274 (130)
  • 635 (65) / 1764 (180)
liquefied:
  • - nominal
  • - minimum / maximum
  • 2940 (300)
  • 1960(200) / 3528(360)
Rated thermal power, W (Kcal/h) 17445 (15000) 23260 (20000) Heating of premises with heat loss no more than, W 14500 14500 19500 19500 Estimated area of ​​a heated room with a height of H = 2.7 m, depending on the climatic conditions of the area, m 2, up to 150 200 Gas consumption:
    - natural with a density of 0.73 kg / m 3 at a pressure of 1274 Pa (130 mm water column) m 3 / h, not more
1,87 2,55
    - liquefied with a gas phase density of 2.0 kg / m 3, at a pressure of 2940 Pa (300 mm of water column) m 3 / h (kg / h), no more
0,65 (1,3) 0,87 (1,74) Vacuum in the chimney, Pa (mm water column)
minimum / maximum 2,94 (0,3) / 29,4 (3,0) Tightness of gas communications, locking device, safety valve, thermostatic valve. Allowed air leakage, cm 3 / h, no more 70 Ignition time, sec., no more 60 Carbon monoxide index, vol.%, no more 0,05 Range of maintenance of water temperature in the heat exchanger, o С 45-90 (Economy, Economy plus (01), Comfort)
30-90 (Economy plus (02), Universal) Burner type injection Tank capacity, l 64 61 62 59 Outer diameter of the connecting branch pipe of the gas exhaust device, mm 136±2 Connecting thread fittings for: - gas supply G 3/4 - supply and discharge of water to the heating part G2 - supply and discharge of water to the heating part - G 1/2 - G 1/2 Water consumption in the mode of hot water supply when heated to At=35 o С l/min., not less than - 5,4 - 7,1 Water pressure in front of the device in the DHW system, kPa (kg / cm 2) - maximum - 588 (6,0) - 588 (6,0) - minimum - 14,7(0,15) - 14,7(0,15) Water pressure in the heating system, kPa (bar), no more 200 (2,0) Distance from the floor to the axis of the inlet pipe of the gas pipeline, mm 716±5 Distance from the floor to the end of the outlet pipe of the heat exchanger, mm 1050±5 Distance from the floor to the axis of the inlet branch pipe of the heat exchanger, mm 292±5 Distance from the floor to the axis of the inlet pipe of the coil, mm - 587±5 - 587±5 Distance from the floor to the axis of the outlet pipe of the coil, mm - 927±5 - 927±5 Overall dimensions, mm: height x width x depth 1050±5 x 420±5 x 480±5 Mass of the device (without packaging), kg, no more 49 57 52 60

Domestic gas heating appliances with water circuit AOGV-17.4-3 Comfort; AOGV-23,2-3 Comfort are designed for water heating of residential and service premises equipped with water heating systems (CO). Combined household gas appliances with a water circuit AKGV-17.4-3 Comfort; AKGV-23,2-3 Comfort are designed for heating and hot water supply of residential and service premises equipped with water heating and hot water supply (DHW) systems. Before using the machine, carefully read the rules and recommendations contained in this manual.

ATTENTION! After the device is sold to the buyer, the manufacturer does not accept claims for incompleteness and mechanical damage.

ATTENTION! Installation, commissioning of the apparatus and instruction are carried out by specialists of the gas service, the service department of the manufacturer or specialized installation services that have a license (permit) for this type of work, with the obligatory filling in of the control coupon for the installation of the apparatus, signature and seal.

The device works on natural and liquefied gases.
The manufacturer supplies devices with nozzles for natural gas. To work on liquefied gas, it is necessary to replace the nozzles for natural gas with nozzles for liquefied gas and reconfigure the gas flow regulator in the automation unit.

NOTE. LPG nozzles are supplied by the factory at the request of the buyer for a fee.

Water is used as a heat carrier in accordance with GOST R 51232-98 and SanPiN 2.1.4.1074-01 with a carbonate hardness of not more than 2 mg. equiv/l. It is allowed for devices AOGV-17.4-3 Comfort, AOGV-23.2-3 Comfort to use low-freezing liquid instead of water - household antifreeze Not Вlood, “Dixis”, “ Warm house - 65”.

These devices can be installed in a closed heating system with a membrane-type expansion tank. The pressure in CO in working condition (at the coolant temperature in CO from 60 to 80 °C) should be no more than 1.5 kgf/cm2.
A safety valve must be installed on the riser (outlet pipe), adjusted to operate at a pressure in the heating system of 1.8 ± 0.1 kgf / cm 2.
To control the pressure in CO, a pressure gauge with a measurement range of 0 to 4 kgf / cm 2 must be installed.

NOTE.

The automation unit provides automatic smooth regulation of gas flow in the range from 100% to 60% of the burner power, depending on the temperature of the coolant in the heat exchanger of the apparatus. When approaching the set temperature of the coolant, the burner switches to the "small flame" mode and when the set temperature of the coolant in the heat exchanger of the apparatus is reached, the main burner is completely turned off. When the set temperature of the heat carrier in the heat exchanger of the device decreases (no more than 15 ° C), the main burner automatically ignites smoothly.

The machine is maintained by the owner. Installation, initial start-up of the apparatus must be carried out only by the gas facilities, the service department of the manufacturer or specialized installation services that have a license (permit) for this type of work.

ATTENTION! It is forbidden to leave the working device unattended for a long time (more than a day).

  1. The appliance must be connected to a separate chimney.
  2. It is forbidden to use a ventilation duct and other ducts not intended for this as a chimney.
  3. It is forbidden to ignite it in case of emergency shutdown of the device without finding out and eliminating the cause of the shutdown.
  4. Forbidden in the device AKGV-17,4-3 Comfort and AKGV-23,2-3 Comfort use in CO as a coolant instead of water antifreeze.

ATTENTION! Work on installation, connection and commissioning of the device is carried out gas facilities, service or specialized installation services who have a license (permit) for this type of work, according to a project agreed with the operating organization (trust) of the gas facilities. The service specialist who starts the gas must instruct the user on the rules for using and caring for the device, making an entry in the control coupon (Appendix A) with mandatory confirmation by signature and seal. In the absence of these records, the control ticket will be invalid and warranty repairs are not performed.

ATTENTION! Preventive inspection and repair of the device is carried out by specialists of the gas industry, service department manufacturer, a service department that has a license (permit) for this type of work.

ATTENTION! It is the responsibility of the owner to supervise the operation of the apparatus and to keep the apparatus clean and in good repair.

NOTE. There may be slight discrepancies between the description and design of the device, which are associated with its constant technical improvement.

LIST OF MANDATORY PREVENTIVE WORK CARRIED OUT BY THE SERVICE SERVICE
Name of works Periodicity of work performance
1 2
Cleaning nozzles of the main and pilot burners, heat exchanger pipes, filter As needed
Checking the tightness of all connections As needed
Checking the draft in the chimney and the free rotation of the draft interrupter door As needed, but at least once a year
Cleaning the thermocouple from carbon deposits As needed
Checking the performance of automation for traction, overheating As needed
Checking the operation of safety automation by flame and thermostat As needed
Checking the operation of the piezo ignition As needed
Cleaning the burner grooves in the upper part of the burner with a metal brush from scale, soot, condensate salts. After cleaning, blow out the burner with air As needed
Soot removal from turbulators As needed. Burning of the lower ends of the turbulators during operation to a length of 5° - 7° mm does not affect the operation of the product and is not a defect
Replacement parts and repairs As needed

WARRANTY

  1. The device complies with the requirements of GOST 20219-74, TU 1-01-0893-90.
  2. The warranty period is 36 months from the date of sale, but not more than 48 months from the date of release of the device by the manufacturer. In the absence of a stamp of a trading organization, the warranty period is 36 months and is calculated from the date of issue of the device.
  3. The manufacturer guarantees trouble-free operation of the device, provided that the consumer observes the rules of operation, care and storage given in this manual.
  4. Warranty repair of the device is not performed in the following cases:
    1. non-compliance with safety requirements;
    2. non-observance of the rules of installation and connection of the device;
    3. non-compliance with the rules of operation, maintenance, repair and maintenance of the device;
    4. negligence of storage, handling, transportation of the device by the owner or trading organization;
    5. use in devices AKGV-17.4-3 Comfort and AKGV-23.2-3 Comfort as a heat carrier instead of water of any other liquid;
    6. as well as for other reasons beyond the control of the manufacturer.
  5. The device is accepted for warranty repair subject to the following requirements:
    1. an employee of the gas industry, a specialist of a service that has a license (permit) for this type of work, together with the owner of the apparatus, draws up an act, which indicates the following:
    2. factory number;
    3. release date;
    4. date of sale;
    5. description of the defect;
    6. preliminary reason for its occurrence.
Manufacturing firm:

Description Gas boiler AOGV-17.4-3 Economy:

The boiler is placed on the site as a customer support for the correct selection of spare parts.
Purpose: For heating
Fuel type: Natural (main) gas or liquefied (balloon) gas

Boiler independent of electricity
Boiler automation: Gas valve ZhMZ
Power, kW: 17.4
Dimensions: 1055 mm x W 425 mm x D 485 mm
Maximum working pressure: 1.5 atm. (Use open expansion tank)
Boiler tank volume: 64 l
Chimney diameter: 135 mm
Connection fitting diameters:
- gas - 3/4""
- inlet / outlet of the heating part - 2 ""
Gas consumption, no more than - 1.87 m3 per hour
Liquefied no more - 1.3 kg per hour
Weight: 49 kg
Consumable parts for this model:
- thermocouple for boilers AOGV-17.4 and AKGV-17.4 Economy, manufactured before 1.07.1996 - article number
- thermocouple for boilers AOGV-17.4 and AKGV-17.4 Economy manufactured from 06/01/1996 to 02/2002 - article number
- thermocouple for boilers AOGV-17.4 and AKGV-17.4 Economy of release 02.2002 to 01.02.2003 - article
- thermocouple for boilers AOGV-17.4 and AKGV-17.4 Economy manufactured from 05.2004 - article - the same for all models
- assembly automation unit for boilers AOGV and AKGV-17.4 Economy of release until 07/01/1999 - article number
- complete automation unit for boilers AOGV and AKGV-17.4 Economy, manufactured before 07/01/2000 - article number
- assembly automation unit for boilers AOGV and AKGV-17.4 Economy of release from 07/01/1999 to 02/2002 - article number
- assembly automation unit for AOGV and AKGV-17.4 Economy boilers, manufactured from 02.2002 - article - bulb-bellows assembly for AOGV and AKGV-17.4 Economy boilers, manufactured before 01.01.1992 - article - bulb-bellows assembly for boilers AOGV and AKGV-17.4 Economy release from 01.01.1992 to 02.2002 - article
To repair the block, see
Please read in the heating system
We strongly recommend to install in systems with an open expansion tank
For normal use recommended antifreeze for open systems
Before installation, please read
Basic knowledge
Answers to frequently asked questions when buying

Distinctive features Gas boiler AOGV-17.4-3 Economy:

Working and practicing repair, we give you eight points to which other boiler manufacturers simply will not give an answer, because the time is not right, and the money is not the same, and the conditions are not the same, and people, too, have already "wasted", so that for their responsibility solve these kinds of questions.

Agree that for the boilers of the Zhukovsky plant this is a real advantage:

1. Availability. The boiler is produced by us. 100%.
2. Availability of spare parts. Here we already answer directly. Parts are and will be. 100%
3. There are NO requirements for the heating system. You don't need to download or set up. If necessary, then open-type expansion tank installed under the ceiling. I poured water with a ladle and it works. 100%
4. There are no requirements for the qualification of the master. No. Any person will start the boiler. Anyone can fix it. 100%
5. Does not require mandatory electricity, stabilizers and pumps. Works by itself. Boiler automation does not require electricity. Very relevant. 100%
6. There is no maintenance of either the system or the boiler itself. There is no service where you need to run a little, otherwise there will be no guarantee. Once you did everything right and calm down - enough for 15-20 years. 100 %
7.Practical experience of the plant itself, and gas facilities, and ordinary people: fathers, mothers, grandmothers and grandfathers with such boilers are very large, from the 50s. Therefore, the Zhukovsky cauldron itself, and our experience of working with it, is a national treasure and a heritage of the time. And this should not be forgotten. 100%
8. Alteration of the boiler, if desired, for liquefied gas is so simple, even primitive and consists only in twisting the nozzles for liquefied gas into the burner and nothing more. 100%

Taking into account all the above points, we advise you to always work with us for the simple reason that our attitude to this work is exactly what you need. Thank you!

Our comment:

Introducing a boiler with a gas valve ZHMZ.

The boiler delivery set includes: The device itself, a draft interrupter, a thermometer, a gasket, a shield, a product passport, valve gaskets (a spare part for a gas block). The draft sensor itself is located on the upper part of the boiler in a special recess in the housing (it is not at all difficult to notice).

A sticker with its number and type is pasted on the inside of the door of each device, the number indicated on this sticker must match the number indicated in the product passport when it was sold. The top of the boiler is covered with a lid, in which small holes are visible - these are turbulators. Through them, the achievement maximum efficiency for this boiler design.

The pipe that exits vertically from the boiler is the heating "supply" pipe. Behind the boiler is a "return" pipe. Both pipes are 2"". Automation is a block with a union nut with a diameter of 3/4 "" for connecting gas and a boiler control unit.

In our case, the bellows-thermoballoon is responsible for adjusting and maintaining the temperature we need in the AOGV Zhukovsky gas boiler with the Economy automation unit. In fact, the bellows mechanically opens gas access to the main burner of the boiler, and when the designated temperature is reached in the boiler, closes this access.

Knowledge base on jets Technic San. 2020.

Everything we know about jets. Year 2020. Open information. Jets. Nozzles. Nozzles. Everything we know today. Publication start date 10.10.2017
Attention! At the end of the article is a constantly updated Knowledge Base on Jets with which we can live and work today. All links are working. Use the links provided in the database. This will make selection much faster. required material and its study. Thank you!

AOGV-17.4-3 Comfort gas floor standing boiler is designed for electrically independent autonomous heating systems for houses, summer cottages up to 140 sq.m. The devices are used in heating systems with natural (open) and forced (closed) circulation of the coolant. The pressure in a closed heating system should be no more than 1.5 kgf / sq.cm.

The heat carrier of the heating system is household antifreeze such as Hot Blood, Dixis, Warm House-65.

The devices work on natural gas, when replacing nozzles (main burner and igniter) - on liquefied (balloon) gas.

heat exchanger

High efficiency of boilers (up to 89%), provided by the tubular design of the heat exchanger with built-in turbulators;

High reliability of the heat exchanger tank due to the use of an automatic welding process and seamless seamless pipes;

Stable supply of hot water for domestic needs in a copper flowing secondary circuit;

The possibility of using boilers in heating systems with natural and forced circulation of the coolant.

Automation

Safety, reliability, simplicity and ease of operation of boilers is ensured by the use of modern Russian automation units;

Saving gas consumption due to the automatic modulation of the burner power in boilers with imported automation;

Ease of control due to the optimal arrangement of automation units.

Burner

Ecological cleanliness due to the low content of nitrogen and carbon oxides in the exhaust gases;

Stable operation of the boiler at low gas pressure in the network (up to 550 Pa);

Ease of use due to the easy process of replacing and cleaning the burner.

Boiler design and packaging

Protective external coating of the boiler with powder white enamel;

Cylindrical and rectangular boilers, automation is located at the top or bottom;

Complete set of boilers with a pointer thermometer and piezo ignition;

Modern convenient packaging of the boiler.